Moni̇tori̇ng transcutaneous oxygen pressure levels duri̇ng and after hyperbari̇c oxygen therapy


Creative Commons License

Thesis Type: Expertise In Medicine

Institution Of The Thesis: Istanbul University, Istanbul Medical Faculty, Division of Medical Sciences , Turkey

Approval Date: 2025

Thesis Language: Turkish

Student: BEKİR ÖZCAN

Supervisor: Şamil Aktaş

Open Archive Collection: AVESIS Open Access Collection

Abstract:

ABSTRACT

This study aims to investigate the changes in transcutaneous oxygen pressure (TcPO₂) levels during and after hyperbaric oxygen therapy (HBOT). The physiological effects of oxygen and HBOT's potential to increase oxygen pressure in tissues were evaluated. Measurements conducted using transcutaneous oxygen monitoring devices revealed a significant increase in tissue oxygen pressure during treatment, with a gradual return to baseline levels post-treatment. The literature review confirms HBOT's effectiveness in enhancing tissue oxygenation, although varying results exist regarding the duration of elevated oxygen pressure after therapy.

The study included nine participants with a mean age of 36.89 ± 12.86 years, consisting of eight patients (four with sudden hearing loss and four with avascular necrosis of the bone) and one healthy volunteer. TcPO₂ measurements were taken from the ventral surface of the right forearm using a transcutaneous oxygen monitor. Measurements were recorded at 15-second intervals before, during, and up to 10 minutes after HBOT.

Statistical analyses were conducted using IBM SPSS 30.0 software; normality was assessed via Kolmogorov-Smirnov and Shapiro-Wilk tests, and differences between measurements were analyzed using Paired Samples T-Test and non-parametric Wilcoxon tests.

The results revealed that TcPO₂ levels significantly increased following HBOT compared to baseline values, remaining elevated for 5-6 minutes before returning to baseline after the 6th minute. This study demonstrates that oxygen does not remain elevated in tissues for an extended period and is rapidly consumed in metabolic processes.