TÜBİTAK Projesi, 2015 - 2017
Tracking charged particles has a wide spectrum of applications in
scientific and industrial projects. The Delay Wire Chamber (DWC) is a
kind of gaseous detector which is a simpler form of the Multi Wire
Proportional Chamber, and was developed by the Beam Instrumentation
Group at CERN. It is preferred in accelerator and particle physics
experiments because of its ease of use, affordability and durability,
and it also provides decent position precision. In this work, we
describe the working principles of the readout electronics of a new DWC
that is being designed and constructed at our laboratory. Results from
the simulation of the circuit and the constructed prototype will be
presented.