Comparison of four different techniques for performing an osteotomy A BIOMECHANICAL, RADIOLOGICAL AND HISTOLOGICAL STUDY ON RABBITS TIBIAS


Elmadag M., Uzer G., Yildiz F., Erden T., Bilsel K., Buyukpinarbasili N., ...Daha Fazla

BONE & JOINT JOURNAL, cilt.97B, sa.12, ss.1628-1633, 2015 (SCI-Expanded) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 97B Sayı: 12
  • Basım Tarihi: 2015
  • Doi Numarası: 10.1302/0301-620x.97b12.36060
  • Dergi Adı: BONE & JOINT JOURNAL
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1628-1633
  • İstanbul Üniversitesi Adresli: Evet

Özet

This animal study compares different methods of performing an osteotomy, including using an Erbium-doped Yttrium Aluminum Garnet laser, histologically, radiologically and biomechanically. A total of 24 New Zealand rabbits were divided into four groups (Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical saw blade and Group IV: laser). A proximal transverse diaphyseal osteotomy was performed on the right tibias of the rabbits after the application of a circular external fixator. The rabbits were killed six weeks after the procedure, the operated tibias were resected and radiographs taken.