DEVELOPMENT AND VALIDATION OF A GC-FID ASSAY FOR DETERMINATION OF FLUVASTATIN IN PHARMACEUTICAL PREPARATIONS


Aslan S., Sagirli O., Ersoy L.

QUIMICA NOVA, cilt.32, sa.9, ss.2347-2350, 2009 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 32 Sayı: 9
  • Basım Tarihi: 2009
  • Doi Numarası: 10.1590/s0100-40422009000900021
  • Dergi Adı: QUIMICA NOVA
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.2347-2350
  • İstanbul Üniversitesi Adresli: Evet

Özet

A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 degrees C for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 mu g mL(-1). The limit of detection and the limit of quantitation were 1.0 and 3.0 mu g mL(-1), respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.