Influence of curing conditions on the long-term release of major resin-matrix monomers from conventional and bulk-fill resin composites: an in vitro liquid chromatography-tandem mass spectrometry study
Materials Research Express, cilt.13, sa.17, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 13 Sayı: 17
- Basım Tarihi: 2026
- Doi Numarası: 10.1088/2053-1591/ae9e88
- Dergi Adı: Materials Research Express
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Chemical Abstracts Core, Compendex, INSPEC, Directory of Open Access Journals, Materials Science & Engineering Collection (ProQuest), Technology Collection (ProQuest)
- Anahtar Kelimeler: bulk-fill composite, light-curing unit, liquid chromatography-tandem mass spectrometry, monomer release, polymerization time
- İstanbul Üniversitesi Adresli: Evet
Özet
This study investigated the long-term release of bisphenol A-glycidyl methacrylate (Bis-GMA), ethoxylated bisphenol A dimethacrylate (Bis-EMA), and urethane dimethacrylate (UDMA) from conventional and bulk-fill resin composites polymerized using different light-curing units and curing times. Three bulk-fill composites and one conventional resin composite were evaluated. Eighty specimens were prepared using standardized metal molds (2 mm × 8 mm for the conventional composite and 4 mm × 8 mm for the bulk-fill composites) and polymerized using either a halogen (Optilux 501) or light-emitting diode (LED; Demi Ultra) curing unit for 20 s or 40 s (n = 5). The specimens were stored in a 75% ethanol/water solution, and monomer release was analyzed after 24 h, 1 week, 1 month, and 6 months using liquid chromatography-tandem mass spectrometry. Data were analyzed using multivariate ANOVA, repeated-measures ANOVA, Tukey HSD, and Tamhane’s T2 tests (α = 0.05). Both curing-unit type and curing time significantly influenced monomer release (p < 0.001). The LED curing unit resulted in lower monomer release than the halogen unit under the tested experimental conditions, while extending curing time from 20 s to 40 s significantly reduced monomer elution. Monomer release remained detectable throughout the six-month observation period. When all experimental conditions were considered collectively, UDMA exhibited the highest overall release and Bis-EMA the lowest, although material- and time-dependent variations were observed. Tetric EvoCeram Bulk Fill released significantly higher amounts of UDMA and Bis-GMA than the other investigated composites (p < 0.001). Within the limitations of this study, both curing conditions and material composition significantly influenced long-term monomer release. These findings highlight the combined contribution of composite formulation and curing protocol to the release behavior of major resin-matrix monomers from contemporary resin composites.