Stress distribution of four implant supported overdentures with tilted standard-sized implants and mini implants


TURP I., TURP V., Tuncel İ., Üşümez A.

European Oral Research, cilt.58, sa.2, ss.95-101, 2024 (ESCI) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 58 Sayı: 2
  • Basım Tarihi: 2024
  • Doi Numarası: 10.26650/eor.20241272144
  • Dergi Adı: European Oral Research
  • Derginin Tarandığı İndeksler: Emerging Sources Citation Index (ESCI), Scopus, TR DİZİN (ULAKBİM)
  • Sayfa Sayıları: ss.95-101
  • Anahtar Kelimeler: finite element analysis, locator, mini-implants, overdenture, Tilted implants
  • İstanbul Üniversitesi Adresli: Evet

Özet

Purpose The goal of the current study is to evaluate the stress distribution when tilted implants and mini-implants are used to support a mandibular overdenture. Materials and Methods Three-dimensional (3D) finite element models of mandibular overdentures were established using four, axial, standard-sized implants (SA model), four standard-sized implants with the mesial ones axial and the distal ones tilted (ST model) and four mini-implants (MA model) with Locator attachments. On each model, a 100 N load was applied to the overdenture in four different directions; bilateral vertical, unilateral vertical and oblique load on the posterior region, and a vertical load on the incisors. The stresses distributed at the peri-implant bone, implants, the prosthetic components, and the overdentures were evaluated. Results Non-axial posterior loading caused higher stress values in the implant and the prosthetic component than axial posterior loading. Lower stress values of the implant and the prosthetic component were observed in the ST model than SA model. The stress distribution in the overdenture at posterior loads were mostly observed around the implants. Conclusion Less prosthetic complications may be expected when the treatment option in the ST model is used. Fatigue fractures may occur around the implants in the overdentures, precautions are advised.