Heteroatom-Doped Carbon Quantum Dots and Polymer Composite as Dual-Mode Nanoprobe for Fluorometric and Colorimetric Determination of Picric Acid


KOÇ K. H., ARDA A., APAK M. R.

ACS Applied Materials and Interfaces, cilt.15, sa.35, ss.42066-42079, 2023 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 15 Sayı: 35
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1021/acsami.3c07938
  • Dergi Adı: ACS Applied Materials and Interfaces
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Chemical Abstracts Core, Compendex, EMBASE, INSPEC, MEDLINE
  • Sayfa Sayıları: ss.42066-42079
  • Anahtar Kelimeler: carbon quantum dots, dual-mode nanosensor, fluorescence quenching, inner filter effect, picric acid detection, PVA-based polymer film
  • İstanbul Üniversitesi Adresli: Hayır

Özet

Oxygen- and nitrogen-heteroatom-doped, water-dispersible, and bright blue-fluorescent carbon dots (ON-CDs) were prepared for the selective and sensitive determination of 2,4,6-trinitrophenol (picric acid, PA). ON-CDs with 49.7% quantum yield were one-pot manufactured by the reflux method using citric acid, d-glucose, and ethylenediamine precursors. The surface morphology of ON-CDs was determined by scanning transmission electron microscopy, high-resolution transmission electron microscopy, dynamic light scattering, Raman, infrared, and X-ray photoelectron spectroscopy techniques, and their photophysical properties were estimated by fluorescence spectroscopy, UV-vis spectroscopy, fluorescence lifetime measurement, and 3D-fluorescence excitation-emission matrix analysis. ON-CDs at an average particle size of 3.0 nm had excitation/emission wavelengths of 355 and 455 nm, respectively. With the dominant inner-filter effect- and hydrogen-bonding interaction-based static fluorescence quenching phenomena supported by ground-state charge-transfer complexation (CTC), the fluorescence of ON-CDs was selectively quenched with PA in the presence of various types of explosives (i.e., 2,4,6-trinitrotoluene, tetryl, 1,3,5-trinitroperhydro-1,3,5-triazine, 1,3,5,7-tetranitro-1,3,5,7-tetraazacyclooctane, pentaerythritol tetranitrate, 3-nitro-1,2,4-triazole-5-one, and TATP-hydrolyzed H2O2). The analytical results showed that the emission intensity varied linearly with a correlation coefficient of 0.9987 over a PA concentration range from 1.0 × 10-9 to 11.0 × 10-9 M. As a result of ground-state interaction (H-bonding and CTC) of ON-CDs with PA, an orange-colored complex was formed different from the characteristic yellow color of PA in an aqueous medium, allowing naked-eye detection of PA. The detection limits for PA with ON-CDs were 12.5 × 10-12 M (12.5 pM) by emission measurement and 9.0 × 10-10 M (0.9 nM) by absorption measurement. In the presence of synthetic explosive mixtures, common soil cations/anions, and camouflage materials, PA was recovered in the range of 95.2 and 102.5%. The developed method was statistically validated against a reference liquid chromatography coupled to tandem mass spectrometry method applied to PA-contaminated soil. In addition, a poly(vinyl alcohol)-based polymer composite film {PF(ON-CDs)} was prepared by incorporating ON-CDs, enabling the smartphone-assisted fluorometric detection of PA.