THE EVALUTION OF NOISE LEVELS IN INTENSIVE CARE UNITS OF HOSPITAL


ÇETİN E., Azizoğlu F., HAPCIOĞLU S. B.

İnternational Congress of Health and Environment, Adana, Turkey, 23 - 25 October 2017, pp.233, (Summary Text)

  • Publication Type: Conference Paper / Summary Text
  • City: Adana
  • Country: Turkey
  • Page Numbers: pp.233
  • Istanbul University Affiliated: Yes

Abstract

THE EVALUTION OF NOISE LEVELS IN INTENS IVE CARE UNITS OF HOSPITAL Ender CETIN1 , Fatma AZIZOGLU2 , Bilge HAPCIOGLU3 1 Istanbul University, Faculty of Engineering, Department of Environmental Engineering, Istanbul-TURKEY 2 Istanbul University, Gstanbul Medical Faculty, Environment Management Department, Istanbul-TURKEY 3 Istanbul Universty Faculty of Medicine, Public Health Department,Istanbul-TURKEY Health is the person's physical, mental and social well-being (WHO). Noise,which is the risk for human health is briefly defined as undesirable sound.Noise is a stress factor even for healthy people, is even more important in the hospitalsespecially in intensive care units.In intensive care units (ICU) , there are many noise sources including central oxygen-dry air system, patient monitor, infusion pump device, ventilator, nutrition device, perfusor device, patient heating-cooling devices. In patients who are exposed to noise in intensive care units; many problems such as heart rate, metabolis m and oxygen consumption, anxiety and pain perception,increased corticosteroid release and decreased respiratory function are common.Furthermore sleep disturbance, stress and intensive care psychosis is another important problem related to noise in intensive care unit patients. The World Health Organisation (WHO) Guidelines for Community Noise includes advice on noise levels in hospitals should not exceed 35 dBA LAeq for areas where patients are treated or observed, with a corresponding LAmax of 40 dBA. Environmental Protection Agency 'Environmental Protection Agency' (EPA) guidelines recommend that the highest sound level should be 45 dB in order to provide a comfortable environment that provides 100% intelligibility within the room, and it is stated that people tend to raise their sound in situations exceeding 45-50 dB. In this study, the sound level was evaluated in intensive care units of a University Hospital. SVANTEK 955, Type 1 noise meter was used. The measurement results were found minimum sound level of 42.6 -55.4 dBA, average sound level of 54.5-66.6 dBA, maximum sound level of 70.2-83.8 dBA. The sound levels in the intensive care units were above the limit values. It was recommended that employees, patients and their relatives must educate about noise. In addition, sound insulation on the walls, floors and ceilings of the building and reducing the setting of the devices such as alarms and telephones or changing their location or producing alternative solutions in order to reduce the noise level to the minimum can be carried out.