THE PREDICTIVE VALUE OF FETAL HEART-RATE MONITORING - A RETROSPECTIVE ANALYSIS OF 2165 HIGH-RISK PREGNANCIES


OCAK V., DEMIRKIRAN F., SEN C., COLGAR U., OCER F., KILAVUZ O., ...Daha Fazla

EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, cilt.44, sa.1, ss.53-58, 1992 (SCI-Expanded) identifier identifier identifier

Özet

The predictive value of fetal heart-rate monitoring on fetal well-being was studied in 2165 high-risk pregnancies. 1883 reactive nonstress test (NST) patterns and 278 nonreactive NST patterns and 4 cases of sinusoidal pattern were obtained. Oxytocin challenge test (OCT) was applied to 263 nonreactive cases.