Accuracy of Two Stereolithographic Guide Systems for Computer-Aided Implant Placement: A Computed Tomography-Based Clinical Comparative Study
JOURNAL OF PERIODONTOLOGY, cilt.81, sa.1, ss.43-51, 2010 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 81 Sayı: 1
- Basım Tarihi: 2010
- Doi Numarası: 10.1902/jop.2009.090348
- Dergi Adı: JOURNAL OF PERIODONTOLOGY
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.43-51
- İstanbul Üniversitesi Adresli: Evet
Özet
Background: Stereo lithographic surgical guides provide significant benefits during the simultaneous placement of multiple implants with regard to the final prosthetic plan. However, deviation from the planning poses a significant risk. Deviations of implants that were placed by bone-, tooth-, and mucosa-supported stereolithographic surgical guides were examined in this study.