Corrosion Atlas Case Studies, Fuad Khoshnaw Rolf Gubner, Editör, Elsevier Science, Oxford/Amsterdam , Oxford, ss.58, 2021
The stagnant water conditions for a long time caused biofilm formation on the surfaces. Corrosion
damage was a consequence of microbial activity of different bacterial groups impairing locally the
passivation layer of stainless steel. Microorganisms of the sulfur-, iron-, and manganese-cycles jointly
caused the problem.