Synthesis of Polycaprolactone Films by Melt Electrowriting Method
X. Polymer Science and Technology Congress with International Participation (PolimerTR 2026), İstanbul, Turkey, 16 September 2026, pp.278-279, (Summary Text)
- Publication Type: Conference Paper / Summary Text
- City: İstanbul
- Country: Turkey
- Page Numbers: pp.278-279
- Open Archive Collection: AVESIS Open Access Collection
- Istanbul University Affiliated: Yes
Abstract
Melt Electrowriting (MEW) is an advanced additive manufacturing technology that combines electrospinning principles with high-precisionextrusion, enabling the fabrication of well-defined microfibrous scaffolds. In MEW, the electric potential difference is applied to a meltedpolymer complex rather than to a polymer solution, so the polymer is brought into a liquid state by heating instead of being dissolved in asolvent. This study investigates the printability, morphological structural differences, and surface/color characteristics of neat Poly(ε-caprolactone) (PCL) films fabricated via MEW method using the Axolotl MEW Biosystem. PLC (ESUN 1000C, Mw ≈ 100 kDa) was utilizedand its films were fabricated using an Axolotl Biosystems printer (Istanbul, Türkiye) equipped with MEW printhed, voltage power supply, andair comporessor. Printing was performed at 170°C, 3.5 kV, 30 mm/s, and 35 psi, utilizing 3cc stainless steel cartridge and brass nozzle, whilesample-specific printing parameters are presented in Table 1.
Table 1. MEW
printing conditions.
|
Sample |
Layer Height (mm) |
Density (%) |
Surface Offset (mm) |
Perimeter Count |
Nozzle (mm)
|
|
PCL1 |
0.20 |
50 |
5.0 |
1 |
0.5 |
|
PCL2 |
0.10 |
100 |
3.5 |
1 |
0.2 |
|
PCL3 |
0.20 |
100 |
3.5 |
3 |
0.2 |
|
PCL4 |
0.10 |
100 |
3.5 |
3 |
0.2 |
The
apparent contact angles estimated from the droplet profiles were 105°, 75°,
110°, and 95° for P1, P2, P3, and P4, respectively. L*, a*, b*,
and chroma and 8° gloss values were presented in Table 2.
Films colours was measured using a YS3010 spectrocolorimeter, while surfacewettability was evaluated by contact angle measurements using a KRUSS DSA25S goniometer. The apparent contact angles estimated from the droplet profiles were 105°, 75°, 110°, and 95° for P1, P2, P3, and P4, respectively. L*, a*, b*,and chroma and 8° gloss values were presented in Table 2.
Table 2. Colour
parameters of PCL films.
|
Sample |
L* |
a* |
b* |
Chroma
Value |
8°
gloss |
|
PCL1 |
51.34±0.38 |
-0.850
± 0.02 |
1.830±
0.06 |
1.490±0.23 |
13.40±10.5 |
|
PCL2 |
22.34±
0.1 |
-0.020±0.01 |
-0.270±0.04 |
0.280±0.04 |
1.020±0.33 |
|
PCL3 |
18.40±0.01 |
0±
0.02 |
-0.490±0.05 |
0.490±0.05 |
0.470±0.28 |
|
PCL4 |
19.29±0.02 |
-0.070±0.06 |
-0.36±0.07 |
0.360±0.08 |
0.29±0.26 |