The CMS trigger system


Khachatryan V., Sirunyan A. M., Tumasyan A., Adam W., Asilar E., Bergauer T., ...Daha Fazla

Journal of Instrumentation, cilt.12, sa.1, 2017 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 12 Sayı: 1
  • Basım Tarihi: 2017
  • Doi Numarası: 10.1088/1748-0221/12/01/p01020
  • Dergi Adı: Journal of Instrumentation
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Anahtar Kelimeler: Trigger concepts and systems (hardware and software), Trigger detectors, Data acquisition circuits, MUON SYSTEM, PERFORMANCE, TRACK
  • İstanbul Üniversitesi Adresli: Evet

Özet

© CERN 2017 for the benefit of the CMS collaboration..This paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics interest from a GHz (MHz) interaction rate of proton-proton (heavy ion) collisions. The first level of the trigger is implemented in hardware, and selects events containing detector signals consistent with an electron, photon, muon, τ lepton, jet, or missing transverse energy. A programmable menu of up to 128 object-based algorithms is used to select events for subsequent processing. The trigger thresholds are adjusted to the LHC instantaneous luminosity during data taking in order to restrict the output rate to 100 kHz, the upper limit imposed by the CMS readout electronics. The second level, implemented in software, further refines the purity of the output stream, selecting an average rate of 400 Hz for offline event storage. The objectives, strategy and performance of the trigger system during the LHC Run 1 are described.