Direct electrosynthesis of carbon nanocomposite interfaces for robust caffeine electroanalysis
Diamond and Related Materials, cilt.170, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 170
- Basım Tarihi: 2026
- Doi Numarası: 10.1016/j.diamond.2026.114230
- Dergi Adı: Diamond and Related Materials
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Chemical Abstracts Core, Chimica, Compendex, INSPEC, Academic Search Ultimate (EBSCO), Engineering Source (EBSCO)
- Anahtar Kelimeler: Caffeine, Differential pulse voltammetry, Electrochemical sensor, Functionalized multi-walled carbon nanotubes, Sulfur-doped graphene oxide
- İstanbul Üniversitesi Adresli: Evet
Özet
Caffeine is one of the most widely consumed psychoactive compounds worldwide, making its rapid and reliable determination increasingly important in pharmaceutical, food, and biological analyses. Although chromatographic techniques such as HPLC provide excellent analytical performance, they generally require expensive instrumentation, labor-intensive sample pretreatment, and centralized laboratory facilities, limiting their suitability for rapid and routine analyses. Electrochemical sensors have emerged as an attractive alternative because they enable direct analysis with minimal sample preparation, rapid response, low cost, portability, and reduced susceptibility to electrode fouling through appropriate surface engineering. In the current investigation, a new pencil graphite electrode (PGE) modified with functionalized multi-walled carbon nanotubes (f-MWCNTs) and sulfur-doped graphene oxide (S-GO) was fabricated through a simple one-step chronoamperometric electrodeposition method for the ultrasensitive electrochemical determination of caffeine. The structural and morphological characteristics of the fabricated electrode were confirmed by scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FT-IR), Raman spectroscopy, and X-ray diffraction (XRD). The electrochemical behavior of the modified electrode was systematically evaluated by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The effects of electrodeposition time, electrodeposition potential, sulfuric acid concentration, f-MWCNT loading, supporting electrolyte, solution pH, and scan rate were comprehensively optimized. Under the optimized experimental conditions, the proposed sensor exhibited a wide linear concentration range from 1.0 × 10−3 to 1.0 × 10−5 M and 5.0 × 10−6 to 1.0 × 10−8 M, with a low detection limit (LOD) of 6.25 × 10−9 M and a limit of quantification (LOQ) of 2.08 × 10−8 M. The sensor also demonstrated excellent reproducibility (RSD = 2.70%) and enhanced charge-transfer characteristics owing to the synergistic combination of S-GO and f-MWCNTs, which increased the electrochemically active surface area and facilitated heterogeneous electron transfer. Recovery values ranging from 97.12% to 104.02% were obtained for pharmaceutical formulations, commercial beverages, blood serum, and urine samples, confirming the reliability of the proposed method for complex sample matrices. The facile one-step fabrication procedure, high sensitivity, broad analytical range, and successful application to real samples demonstrate that the developed f-MWCNT/S-GO/PGE sensor represents a simple and practically applicable electrochemical platform for caffeine determination.