Effect of offset lines in Doherty power amplifiers


Aydin O., Palamutcuogullari O., Yarman B. S. B.

IEICE ELECTRONICS EXPRESS, vol.12, no.24, 2015 (SCI-Expanded) identifier identifier

  • Publication Type: Article / Article
  • Volume: 12 Issue: 24
  • Publication Date: 2015
  • Doi Number: 10.1587/elex.12.20150867
  • Journal Name: IEICE ELECTRONICS EXPRESS
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Istanbul University Affiliated: Yes

Abstract

In this paper, main and peaking voltages of a Doherty power amplifier are derived by means of the chain parameters of the output section to analyze the effect of the offset lines on the drain efficiency. It is shown that the main branch offset line dominates the drain efficiency. Furthermore, it is exhibited that moderate offset mismatch at the peaking branch has no significant influence on the output power performance of the amplifier. A 100W GaN Doherty power amplifier is realized to experimentally verify the results.