Clinical applicability of the substitution of mixed venous oxygen saturation with central venous oxygen saturation.
Journal of cardiothoracic and vascular anesthesia, cilt.15, sa.5, ss.574-9, 2001 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 15 Sayı: 5
- Basım Tarihi: 2001
- Doi Numarası: 10.1053/jcan.2001.26534
- Dergi Adı: Journal of cardiothoracic and vascular anesthesia
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.574-9
- Anahtar Kelimeler: central venous oxygen saturation, mixed venous oxygen saturation, cardiac index, arterial carbon dioxide tension, oxygen extraction ratio, sepsis, general anesthesia, RANDOMIZED TRIAL, SURGERY, SHOCK
- İstanbul Üniversitesi Adresli: Evet
Özet
Objective: To examine the clinical applicability of substituting central venous oxygen saturation (ScvO(2)) for mixed venous oxygen saturation (SmvO(2)) in monitoring global tissue oxygenation.