Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam
JOURNAL OF INSTRUMENTATION, vol.13, 2018 (SCI-Expanded, Scopus)
- Publication Type: Article / Article
- Volume: 13
- Publication Date: 2018
- Doi Number: 10.1088/1748-0221/13/01/p01002
- Journal Name: JOURNAL OF INSTRUMENTATION
- Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Keywords: Calorimeters, Radiation-hard detectors, Scintillators and scintillating fibres and light guides
- Istanbul University Affiliated: Yes
Abstract
We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillators, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the signal timing for blue and green scintillators.