Tracking failure and recurrence plot analysis for three different levels in the discharge on epoxy resin


Ispirli M. M., Yilmaz A. E.

National Conference on Electrical, Electronics and Biomedical Engineering (ELECO), Bursa, Turkey, 1 - 03 December 2016, pp.349-353 identifier

  • Publication Type: Conference Paper / Full Text
  • Volume:
  • City: Bursa
  • Country: Turkey
  • Page Numbers: pp.349-353
  • Istanbul University Affiliated: Yes

Abstract

Electric energy requirement is increasing day by day, so excessive demand for the transmission of high voltage and current has brought problems in high voltage insulation. The polymers used for electrical insulation in the external environment is exposed to environmental conditions. In this paper, ASTM D5288 standards is used to simulate this environmental stresses. In this standard tracking failure of pure epoxy resin samples are investigated. During the expriment, 3., 20. and 50. drop the instant evaporation mechanism obtained through discharge currents, that they were analyzed by the recurrence plot method.